2000VA CyberPower Online S Tower Online UPS OLS2000E 2 Year Adv Replacement Warranty, *Bonus Cyberpower SNMP Card

Web ID: 20490

CyberPower Online S 2000VA/1600W (10A) Tower Online UPS, (OLS2000E) -2 Yr Adv Replacement Warranty 2 yr Int. Batteries, BONUS CyberPower RMCARD205 SNMP Remote Management Card for UPS
Manufacturer Warranty: 2 Year
Manufacturer PN: OLS2000E
GTIN: 4712856271324
Manufacturer Website

$1149 

CyberPower OLS2000E is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment. By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 96%. The product is equipped with a Maintenance Bypass Switch. By flipping the switch, the power supply is safely transferred to utility. This allows service personnel to carry out fast on-site maintenance without having to shut down any connected equipment.

FEATURES

  • Online (Double Conversion) UPS Topology
  • Energy Saving Technology
  • Generator Compatible
  • Overload Protection
  • Zero Transfer Time
  • Smart Battery Management (SBM)
  • External Battery Module (EBM)
  • Surge and Spike Protection
  • EMI and RFI Filtration
  • Phone/ Fax/ Modem/ DSL/ Network Protection
  • LCD Status Display
  • Emergency Power Off (EPO) Port
  • PowerPanel® Management Software
  • SNMP/ HTTP Remote Management Capability
  • Tower Form Factor

TYPICAL APPLICATION

  • Data Closets
  • NAS & Servers
  • Home Theater Systems
  • DVRs/Surveillance Systems
  • POS Systems
  • Transportation & Infrastructure
  • Vehicle/Yacht
  • Emergency Systems
  • Electric Lighting
  • Back Office
  • Server Room
  • Data Center

FEATURE FOCUS

Extended Runtime

Extended runtime is critical for most power demanding electronic devices. The installation of CyberPower's external battery modules allows scalable system runtime, guaranteeing higher system availability that ensures clean, uninterrupted power to protected equipment even during a power outage.

Smart Battery Management

Batteries are normally consider as a consumable item that requires replacement on a regular basis. To further prolong battery life span, UPS adopted with Smart Battery Management technology uses a 3-cycle approach and temperature compensation method which efficiently reduces battery maintenance cost and achieves a lower total cost of ownership.

GENERAL

UPS Topology

Online Double Conversion

Energy Saving Technology

Online ECO Mode Efficiency > 95%

Active PFC Compatibility

Yes

INPUT

Generator Compatibility

Yes

Nominal Input Voltage (Vac)

230 ± 10%

Input Voltage Range (Vac)

160 ~ 300

Adjustable Voltage Range (Vac)

0~50% Load for 110 ~ 300 Vac
0~60% Load for 120 ~ 300 Vac
0~80% Load for 140 ~ 300 Vac
0~100% Load for 160 ~ 300 Vac

Input Frequency (Hz)

50 ± 10
60 ± 10

Input Frequency Detection

Auto-sensing

Rated Input Current (A)

9

Input Power Factor

0.98

Input Connector Type

IEC C20

Detachable Power Cord Plug Type

AU

Power Cord Length (ft.)

5.9

Power Cord Length (m.)

1.8

OUTPUT

Capacity (VA)

2000

Capacity (Watts)

1800

On Battery Waveform

Pure Sine Wave

On Battery Voltage(s) (Vac)

208 ± 1%
220 ± 1%
230 ± 1%
240 ± 1%

Output Voltage Setting

Configurable

On Battery Frequency (Hz)

50 ± 0.5%
60 ± 0.5%

Output Frequency Setting

Configurable

Power Factor

0.9

ECO Mode Voltage Tolerance

± 15 %

Overload Protection

Internal Current Limiting , Circuit Breaker , Fuse

Overload Protection (Line Mode)

110~120% Load for 1 min, >120% Load Immediately

Overload Protection (Battery Mode)

110~120% Load for 10 sec, >120% Load Immediately

Overload Protection (Bypass Mode)

>130% Load Immediately

Crest Factor

3 : 1

Harmonic Distortion (Linear Load)

THD<3%

Harmonic Distortion (Non-linear Load)

THD<5%

Internal Bypass

Automatic Bypass , Manual Bypass

Outlet(s) - Total

5

Outlet Type

Hardwire Terminal Block x 1
IEC C13 x 4

Outlet(s) - Battery & Surge Protected

4

Typical Transfer Time (ms)

0

BATTERY

Runtime at Half Load (min)

15

Runtime at Full Load (min)

5

Typical Recharge Time (Hours)

5

Maximum Charging Current (A)

1

Start On Battery

Yes

Smart Battery Management (SBM)

Yes

User Replaceable

No

Battery Type

Sealed Lead-acid

Single Battery Capacity (AH)

12 V 7 AH

External Battery Module (EBM)

BPSE72V45A

Max. EBM Quantity

3

SURGE PROTECTION & FILTERING

Surge Suppression (Joules)

440

EMI/RFI Filtration

Yes

Phone/Network Protection RJ11/RJ45 (Combo)

1-in, 1-out

Phone Protection RJ11

1-in, 1-out

MANAGEMENT & COMMUNICATIONS

LCD Panel

Yes

LCD Information Display

Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information , Event & Log

LCD Setting & Control

Mode Setting , Alarm Setting , Input & Output , Battery Setting

HID Compliant USB Port(s)

1

Serial Port

RS232

Emergency Power Off (EPO) Port

Yes

Audible Alarms

Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault , Replace Battery

Power Management Software

PowerPanel® Business Edition

SNMP / HTTP Remote Monitoring

Yes - with optional RMCARD205

PHYSICAL

Form Factor

Tower

Enclosure Construction

Metal

Color

Black

PHYSICAL SIZE - UPS MODULE

Dimensions (WxHxD) (in.)

7.72 x 12.27 x 16.38

Dimensions (WxHxD) (mm.)

196 x 337 x 416

Weight (lbs.)

52.47

Weight (kg.)

23.8

SHIPPING DIMENSIONS

Dimensions (WxHxD) (in.)

11.61 x 18.03 x 20.43

Dimensions (WxHxD) (mm.)

295 x 458 x 519

Weight (lbs.)

57.32

Weight (kg.)

26

ENVIRONMENTAL

Operating Temperature (°F)

32 ~ 104

Operating Temperature (°C)

0 ~ 40

Operating Relative Humidity (Non-condensing) (%)

20 ~ 90

Operating Elevation (feet/meters)

0-5,000 feet (0-1,500 meters)

Storage Temperature (°F)

-4 ~ 122

Storage Temperature (°C)

-20 ~ 50

Storage Relative Humidity (Non-condensing) (%)

10 ~ 90

Storage Elevation (feet/meters)

0-5,000 feet (0-1,500 meters)

Online Thermal Dissipation (BTU/hr)

666

Audible Noise at 1.5M from Surface of Unit (dBA)

45

CERTIFICATIONS

Certifications

CE , RCM

RoHS

Yes

WARRANTY

Product Warranty Period (Year)2

Battery Warranty Period (Year)2