48 Port TP-Link SG6654XHP Omada Gigabit Stackable L3 Managed PoE+ Switch with 6 10G Slots
Web ID: 40177
LAN Speed: Gigabit || 10 Gigabit
Ports: 48 Port
Switch Tech: Power over Ethernet Switch || Managed
Power Supply: 1440W
ONLY WHILE STOCKS LAST!
Manufacturer Warranty: 5 Year
Manufacturer PN: SG6654XHP
Manufacturer Website
What This Product Does
Omada SG6654XHP, an advanced L3 managed PoE+ switch, is crafted for convergence layer requirements with features like L3 routing, rapid 10 Gbps wired connectivity, stacking, and redundant power supplies. It offers an impressive 1440 W PoE budget,* 48× gigabit RJ45 PoE+ ports, 6× 10 Gbps SFP+ slots, and physical stacking. Combined with centralized management, strong security, and comprehensive management features, SG6654XHP is an ideal, reliable network solution for SMBs, enterprises, and ISPs.
IEEE 802.3at/af-compliant Power over Ethernet
48× IEEE 802.3at/af-compliant PoE ports supply up to 1440 W total power to 802.3at and 802.3af devices,* with each port supplying up to 30 W power. Set up wireless access points, surveillance cameras, IP phones, and other PoE devices quickly and easily, without the hassle and cost of installing power cabling.
High-speed Connectivity and Powerful Stacking
48 gigabit RJ45 ports and 6× 10 Gbps SFP+ slots provide up to 216 Gbps switching capacity per unit. Up to 4 units of physical stacking with up to 864 Gbps switching capacity empower the networking structure with built-in redundancy and performance.
Abundant Layer 3 Capabilities
Comes with abundant Layer 3 routing protocols that support a scalable network. Static Routing, RIP, OSPF, ECMP, VRRP, DHCP Server, and DHCP Relay are supported. PIM-DM multicast routing protocol guarantees efficient routing for multicast groups.
Highly Available
Optional field-replaceable and hot-swappable redundant power supplies and VRRP make it an ideal choice for reliable networking architecture.** ERPS supports rapid protection and recovery in a ring topology.
Enhanced Security Functions
Defend against a range of network threats with ACL support (IPv4 & IPv6), Dynamic ARP Inspection, IEEE 802.1X, MAB, Port Security, and Secure Shell.
Omada SDN
Integration into the Omada system brings centralized cloud management and a series of management features such as Zero-Touch Provisioning (ZTP).‡ The Omada Software Defined Networking (SDN) platform integrates network devices, including access points, switches, and routers, providing 100% centralized cloud management—all controlled from a single interface.
Apart from the ability to be centrally managed via the web or the Omada app, SG6654XHP is also easy to manage via an intuitive web-based Graphical User Interface (GUI) or an industry-standard Command Line Interface (CLI). For both management methods, traffic is protected through SSL or SSH encryption. SNMP (v1/v2c/v3) and RMON support enable the switch to be polled for valuable status information and to send traps for abnormal events.
HARDWARE FEATURES | |
---|---|
Interface | • 48× 10/100/1000 Mbps PoE+ RJ45 Ports • 6× 10G SFP+ Slots • 2× USB 2.0 Ports • 1× RJ45 Console Port • 1× USB Type-C Console Port • 1× RJ45 Management Port |
Fan Quantity | Four Field-replaceable and Hot-swappable Fans |
Power Supply | Two Field-replaceable and Hot-swappable Power Supply Modules** (100–240 VAC, 50/60 Hz) **Shipping with one PSM900-AC module by default, and another field-replaceable redundant power supply requires purchasing separately. |
PoE Ports (RJ45) | • Standard: 802.3at/af compliant • PoE+ Ports: 48 Ports, up to 30 W per port • PoE Power Budget: up to 1440 W* *The total PoE budget varies with the power supply modules. |
Dimensions ( W x D x H ) | 17.3 × 16.5 × 1.7 in (440 × 420 × 44 mm) |
Mounting | Rackmountable |
Max Power Consumption | • 67.24 W (110 V/60 Hz) (With no PD connected) • 1767.7 W (110 V/60 Hz) (With 1440W PD connected and powered by 2× PSM900-AC) |
Max Heat Dissipation | • 229.29 BTU/hr (110 V/60 Hz) (With no PD connected) • 6,027.86 BTU/hr (110 V/60 Hz) (With 1440W PD connected and powered by 2× PSM900-AC) |
PERFORMANCE | |
---|---|
Switching Capacity | 216 Gbps per Unit |
Stacking | • Stacking Number: 4 • Stacking Port: 10G SFP+ Slot (all uplink ports can be used as stacking ports) • Stack Bandwidth: 20 Gbps Per Port (Full-Duplex) |
Packet Forwarding Rate | 160.7 Mpps |
MAC Address Table | 32 K |
Packet Buffer Memory | 3 MB |
Jumbo Frame | 9 KB |
SOFTWARE FEATURES | |
---|---|
Quality of Service | • Class of Service - 8 Queues of Priority - Port Priority - IEEE 802.1p Priority - DSCP Priority - Queue Min-Bandwidth - Schedule Mode (SP, WRR, SP+WRR) • Bandwidth Control - Rate Limit - Storm Control • Voice VLAN • User-Defined OUI • Smoother Performance • Action for Flows - QoS remark (802.1P Remark, DSCP Remark) |
L3 Features | • IP Interfaces: - IPv4: Max 256, IPv6: Max 256 • Static Routing - Max 1,024, IPv6: Max 512 • Host Route Table: Max 6,100 entries • RIP: Version v1/v2, Max 8,190 • OSPF: Version v2/v3; v2: Max 8,190, v3: Max 4,097 • VRRP: Version v2/v3, Max 64 groups • ECMP: 256 entries, max 32 ECMP Nexthops per Destination • Static ARP: 512 static entries • Dynamic ARP: 7,680 dynamic entries • Proxy ARP • DHCP Server: - Max 8K IP Pools - Max 1,000 Manual Binding Entries • DHCP Relay: - Relayed Interface - Relayed VLAN |
L2 and L2+ Features | • Link Aggregation • Spanning Tree Protocol • Port-based and VLAN-based Loopback Detection • 802.3x Flow Control • Supports 2,048 IGMP groups • ERPS • Mirroring • RSPAN • MAC Address Table • PIM-DM (IPv4) • Multicast - IGMP Snooping - MLD Snooping - L2 Multicast Table - Fast Leave - Multicast VLAN Registration (MVR) - Static Multicast IP - Multicast Filtering |
Advanced Features | • Automatic Device Discovery† • Batch Configuration† • Batch Firmware Upgrading† • Intelligent Network Monitoring† • Abnormal Event Warnings† • Unified Configuration† • Reboot Schedule† ISP Features: • 802.3ah Ethernet Link OAM • L2PT (Layer 2 Protocol Tunneling) • Device Link Detect Protocol (DLDP) • DDM • sFlow |
VLAN | • Max 4K VLAN Group (802.1q VLAN) • 802.1Q Tagged VLAN • MAC VLAN Entries: 200 • Multicast VLAN • Management VLAN • VLAN VPN (QinQ): Max 256 entries • GVRP • Protocol VLAN: Protocol Template 16, Protocol VLAN 12 entries • VLAN VPN • Voice VLAN • Private VLAN |
Security | • Port Isolation • CPU-Defend • ARP Inspection (Dynamic ARP Inspection) • DoS Defend • IP-MAC-Port Binding -1,024 Entries - DHCP Snooping - ARP Inspection - IPv4 Source Guard • IPv6-MAC -Port Binding -1,024 Entries - DHCPv6 Snooping - ND Detection - ND Snooping - IPv6 Source Guard • DHCP Filter • Static/Dynamic Port Security - Up to 64 MAC addresses per port • Broadcast/Multicast/Unknown-unicast Storm Control - kbps/ratio control mode • 802.1X - Port base authentication - Mac base authentication - VLAN Assignment - MAB - Guest VLAN - RADIUS authentication and accountability support • AAA (including TACACS+) • Secure web management through HTTPS with SSLv3/TLS 1.2 • Secure Command Line Interface (CLI) management with SSHv2 • IP/Port/MAC-based access control |
MANAGEMENT | |
---|---|
Omada App | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
Centralized Management | • Omada Cloud-Based Controller • Omada Hardware Controller • Omada Software Controller |
Cloud Access | Yes. Requiring the use of Omada Hardware Controller, Omada Cloud-Based Controller, or Omada Software Controller. |
Zero-Touch Provisioning | Yes. Requiring the use of Omada Cloud-Based Controller. |
Management Features | • Web-based GUI • Command Line Interface (CLI) through console port, telnet • SNMPv1/v2c/v3 - Trap/Inform - RMON (1, 2, 3, 9 groups) • SDM Template • DHCP/BOOTP Client • 802.1ab LLDP/LLDP-MED • DHCP Auto Install • Dual Image, Dual Configuration • CPU Monitoring • Cable Diagnostics • Password Recovery • SNTP • System Log • EEE |
OTHERS | |
---|---|
Package Contents | • SG6654XHP Switch • Power Cord • RJ45 Console Cable • Quick Installation Guide • Rackmount Kit • Rubber Feet |
System Requirements | Microsoft® Windows® 98SE, NT, 2000, XP, Vista™ or Windows 7/8/10/11, MAC® OS, NetWare®, UNIX® or Linux. |
Environment | • Operating Temperature: 0–45 ? (32–113 ?); • Storage Temperature: -40–70 ? (-40–158 ?) • Operating Humidity: 10–90% RH non-condensing • Storage Humidity: 5–90% RH non-condensing |