2000VA CyberPower Rack/Tower LCD 2000W Line Interactive UPS PR2000ERTXL2U
Web ID: 11168
CyberPower PR2000ERTXL2U Line-Interactive UPS, with seamless Pure Sine Wave, provides the best power protection available for office system devices including PCs, workstations, networking devices, and peripherals. Its typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment. ONLY WHILE STOCKS LAST!
Manufacturer Warranty: 3 Year
Manufacturer PN: PR2000ERTXL2U
GTIN: 4712364144677
Manufacturer Website
CyberPower PR2000ERTXL2U Line-Interactive UPS, with seamless Pure Sine Wave, provides the best power protection available for office system devices including PCs, workstations, networking devices, and peripherals. It’s typically integrated in the back office, server room, and data center environment. The rackmount / tower convertible design gives it enhanced flexibility for installation and operation in almost any environment. Multiple UPS systems can be connected to a single main Emergency Power Off (EPO) switch. In the event of an emergency, the UPS systems can be shut down immediately with the EPO button. As for battery maintenance, the UPS allows battery hot-swapping, which enables users to perform normal battery maintenance without significant interruption.
FEATURES
- Line-interactive UPS Topology
- Energy Saving Technology
- Active PFC Compatible
- Pure Sine Wave Output
- Automatic Voltage Regulation (AVR)
- Overload Protection
- Critical/ Non-critical Load Outlets
- Hot-swappable Batteries
- Extended Battery Module (EBM)
- Surge and Spike Protection
- EMI and RFI Filtration
- LCD Status Display
- USB Connectivity Port
- Serial Connectivity Port
- Emergency Power Off (EPO) Port
- PowerPanel® Management Software
- SNMP/ HTTP Remote Management Capability
- Rack/ Tower Convertible Configurations
TYPICAL APPLICATION
- PCs & Workstations
- Computers & Laptops
- Printers & Office Devices
- SOHO Networking Devices
- Phone/Fax/Modem
- Telecom & Network Equipment
- Video/Audio Equipment
- Industrial Equipment
- Mission-Critical Equipment
- Generator/Motor/Pump
- Back Office
- Server Room
- Data Center
FEATURE FOCUS
Critical/Noncritical Load Outlets
By dividing the outlets according to the importance of the connected loads, users are offered the flexibility to wisely manage the limited battery power during the event of power outage. In the state of a power failure, the UPS battery power can be preserve by terminating the power provided to the non-critical outlets, sparing the power to allow more runtime for critical loads to perform graceful shutdown.
Heavy-duty Rackmount Rails Included
The adjustable rackmount rails are engineered to facilitate the rack mounting of UPS or battery modules and support heavy UPS systems. Installation is quick and easy and required mounting hardware is included.
Sturdy Rackmount Ears Included
The rackmount ears are included for flexible rack mounting of UPS or battery modules. For some rack/tower convertible models, the ears also serve as supporting stands to provide stability and keep the unit upright. Installation is quick and easy and required mounting hardware is included.
GENERAL
Phase
Single Phase |
UPS Topology
Line-interactive |
Energy Saving Technology
GreenPower UPS™ Bypass Technology |
Active PFC Compatibility
Yes |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage (Vac)
220 |
230 |
240 |
Input Voltage Range (Vac)
159 ~ 288 |
Adjustable Voltage Range (Vac)
151 ~ 302 Vac |
Input Frequency (Hz)
50 ± 3 |
60 ± 3 |
Input Frequency Detection
Auto-sensing |
Rated Input Current (A)
10 |
Input Connector Type
IEC C14 |
Detachable Power Cord Plug Type
AU |
Power Cord Length (ft.)
10 |
Power Cord Length (m.)
3.05 |
OUTPUT
Capacity (VA)
2000 |
Capacity (Watts)
2000 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) (Vac)
220 ± 5% |
230 ± 5% |
240 ± 5% |
On Battery Frequency (Hz)
50 ± 1% |
60 ± 1% |
Power Factor
1 |
Automatic Voltage Regulation (AVR)
Double Boost, Single Buck |
Overload Protection
Internal Current Limiting , Circuit Breaker |
Outlet(s) - Total
10 |
Outlet Type
IEC C13 x 10 |
Outlet(s) - Battery & Surge Protected
10 |
Outlet(s) - Critical Load (CL)
5 |
Outlet(s) - Non-Critical Load (NCL)
5 |
Typical Transfer Time (ms)
4 |
BATTERY
Runtime at Half Load (min)
14 |
Runtime at Full Load (min)
4 |
Typical Recharge Time (Hours)
3 |
Start On Battery
Yes |
User-replaceable
Yes |
Hot-swappable
Yes |
Battery Type
Sealed Lead-acid |
Replacement Battery Pack
RBP0129 |
RBP Quantity (pcs)
1 |
Extended Battery Module (EBM)
BP48VP2U02 (Built-in Charger) |
Max. EBM Quantity (pcs)
Unlimited |
SURGE PROTECTION & FILTERING
Surge Suppression (Joules)
2430 |
EMI/RFI Filtration
Yes |
Network Protection RJ45
1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Orientation
Rotatable LCD panel |
LCD Information Display
Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Event & Log |
LCD Setting & Control
Mode Setting , Alarm Setting , Input & Output , Battery Setting , Communication |
LED Indicators
Power On , Line Mode , Battery Mode , UPS Fault |
HID Compliant USB Port(s)
1 |
Serial Port
RS232 |
Dry Contact (with Relay)
Yes |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault |
Management Cable (pcs)
Power Cord x2 , USB Cable x1 , Serial Cable x1 , EPO Cable x1 , Phone Line x1 |
Power Management Software
PowerPanel® Business Edition |
SNMP / HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Form Factor
Rack/Tower |
Enclosure Construction
Metal |
Color
Black |
Rackmount Rail
Yes |
Rackmount Ears
Yes |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
17.1 x 3.4 x 19.7 |
Dimensions (WxHxD) (mm.)
433 x 86.5 x 500 |
Weight (lbs.)
86 |
Weight (kg.)
39 |
Installed Rack Height (U)
2 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
22.1 x 10.8 x 24.4 |
Dimensions (WxHxD) (mm.)
560 x 275 x 620 |
Weight (lbs.)
91.1 |
Weight (kg.)
41.3 |
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104 |
Operating Temperature (°C)
0 ~ 40 |
Operating Relative Humidity (Non-condensing) (%)
0 ~ 95 |
Operating Elevation (feet/meters)
0-10,000 feet (0-3,000 meters) |
Storage Temperature (°F)
5 ~ 113 |
Storage Temperature (°C)
-15 ~ 45 |
Storage Relative Humidity (Non-condensing) (%)
0 ~ 95 |
Storage Elevation (feet/meters)
0-50,000 feet (0-15,000 meters) |
Online Thermal Dissipation (BTU/hr)
116 |
Audible Noise at 1.0M from Surface of Unit (dBA)
57.5 |
CERTIFICATIONS
Certifications
CE , FCC Class B , UL , RCM , VCCI |
RoHS
Yes |
WARRANTY
Product Warranty Period (Year)3
Battery Warranty Period (Year)2