3000VA CyberPower Online S Tower Online UPS OLS3000E 2 Year Adv Replacement Warranty
Web ID: 20491
CYBERPOWER SYSTEMS Online S 3000VA/2400W Tower UPS, 6* 12V/8.5AH, (4) IEC C13, (1)IEC C19*1, Terminal Block, USB & Serial Port & SNMP Slot, 2 Yrs Adv. Repl Requires 15 Amp wall socket CASH PRICE
Manufacturer Warranty: 2 Year
Manufacturer PN: OLS3000E
GTIN: 4712856271331
Manufacturer Website
CyberPower OLS3000E is a high-performance UPS featuring online double-conversion topology, which provides seamless pure sine wave power for mission-critical devices such as NAS and servers, DVRs/surveillance systems, transportation and infrastructure, and emergency systems. It’s typically integrated in the back office, server room, and data center environment. By manually setting the UPS to ECO Mode, the UPS automatically detects the input power quality and discerns whether it should operate in Line Mode or ECO Mode. Under poor power conditions, the UPS will run in Line Mode, which guarantees the highest level of protection and the best possible power quality. When the input power quality is acceptable, the UPS switches to ECO Mode, which increases the total output power efficiency by up to 96%. The product is equipped with a Maintenance Bypass Switch. By flipping the switch, the power supply is safely transferred to utility. This allows service personnel to carry out fast on-site maintenance without having to shut down any connected equipment.
FEATURES
- Online (Double Conversion) UPS Topology
- Energy Saving Technology
- Generator Compatible
- Overload Protection
- Zero Transfer Time
- Smart Battery Management (SBM)
- External Battery Module (EBM)
- Surge and Spike Protection
- EMI and RFI Filtration
- Phone/ Fax/ Modem/ DSL/ Network Protection
- LCD Status Display
- Emergency Power Off (EPO) Port
- PowerPanel® Management Software
- SNMP/ HTTP Remote Management Capability
- Tower Form Factor
TYPICAL APPLICATION
- Data Closets
- NAS & Servers
- Home Theater Systems
- DVRs/Surveillance Systems
- POS Systems
- Transportation & Infrastructure
- Vehicle/Yacht
- Emergency Systems
- Electric Lighting
- Back Office
- Server Room
- Data Center
FEATURE FOCUS
Extended Runtime
Extended runtime is critical for most power demanding electronic devices. The installation of CyberPower's external battery modules allows scalable system runtime, guaranteeing higher system availability that ensures clean, uninterrupted power to protected equipment even during a power outage.
Smart Battery Management
Batteries are normally consider as a consumable item that requires replacement on a regular basis. To further prolong battery life span, UPS adopted with Smart Battery Management technology uses a 3-cycle approach and temperature compensation method which efficiently reduces battery maintenance cost and achieves a lower total cost of ownership.
GENERAL
UPS Topology
Online Double Conversion |
Energy Saving Technology
Online ECO Mode Efficiency > 95% |
Active PFC Compatibility
Yes |
INPUT
Generator Compatibility
Yes |
Nominal Input Voltage (Vac)
230 ± 10% |
Input Voltage Range (Vac)
190 ~ 300 |
Adjustable Voltage Range (Vac)
0~50% Load for 110 ~ 300 Vac |
0~60% Load for 140 ~ 300 Vac |
0~80% Load for 160 ~ 300 Vac |
0~100% Load for 190 ~ 300 Vac |
Input Frequency (Hz)
50 ± 10 |
60 ± 10 |
Input Frequency Detection
Auto-sensing |
Rated Input Current (A)
13.04 |
Input Power Factor
0.98 |
Input Connector Type
IEC C20 |
Detachable Power Cord Plug Type
AU |
Power Cord Length (ft.)
5.9 |
Power Cord Length (m.)
1.8 |
OUTPUT
Capacity (VA)
3000 |
Capacity (Watts)
2700 |
On Battery Waveform
Pure Sine Wave |
On Battery Voltage(s) (Vac)
208 ± 1% |
220 ± 1% |
230 ± 1% |
240 ± 1% |
Output Voltage Setting
Configurable |
On Battery Frequency (Hz)
50 ± 0.5% |
60 ± 0.5% |
Output Frequency Setting
Configurable |
Power Factor
0.9 |
ECO Mode Voltage Tolerance
± 15 % |
Overload Protection
Internal Current Limiting , Circuit Breaker , Fuse |
Overload Protection (Line Mode)
110~120% Load for 1 min, >120% Load Immediately |
Overload Protection (Battery Mode)
110~120% Load for 10 sec, >120% Load Immediately |
Overload Protection (Bypass Mode)
>130% Load Immediately |
Crest Factor
3 : 1 |
Harmonic Distortion (Linear Load)
THD<3% |
Harmonic Distortion (Non-linear Load)
THD<5% |
Internal Bypass
Automatic Bypass , Manual Bypass |
Outlet(s) - Total
6 |
Outlet Type
IEC C19 x 1 | |
Hardwire Terminal Block x 1 | |
IEC C13 x 4 |
Outlet(s) - Battery & Surge Protected
5 |
Typical Transfer Time (ms)
0 |
BATTERY
Runtime at Half Load (min)
14 |
Runtime at Full Load (min)
4 |
Typical Recharge Time (Hours)
5 |
Maximum Charging Current (A)
1 |
Start On Battery
Yes |
Smart Battery Management (SBM)
Yes |
User Replaceable
No |
Battery Type
Sealed Lead-acid |
Single Battery Capacity (AH)
12 V 9 AH |
External Battery Module (EBM)
BPSE72V45A |
Max. EBM Quantity
3 |
SURGE PROTECTION & FILTERING
Surge Suppression (Joules)
440 |
EMI/RFI Filtration
Yes |
Phone/Network Protection RJ11/RJ45 (Combo)
1-in, 1-out |
Phone Protection RJ11
1-in, 1-out |
MANAGEMENT & COMMUNICATIONS
LCD Panel
Yes |
LCD Information Display
Operation Type , Power Status , Battery Status , Load Status , Fault & Warning , Other Information , Event & Log |
LCD Setting & Control
Mode Setting , Alarm Setting , Input & Output , Battery Setting |
HID Compliant USB Port(s)
1 |
Serial Port
RS232 |
Emergency Power Off (EPO) Port
Yes |
Audible Alarms
Battery Mode , Low Battery , Overload , Overcharge , Overheat , UPS Fault , Replace Battery |
Power Management Software
PowerPanel® Business Edition |
SNMP / HTTP Remote Monitoring
Yes - with optional RMCARD205 |
PHYSICAL
Form Factor
Tower |
Enclosure Construction
Metal |
Color
Black |
PHYSICAL SIZE - UPS MODULE
Dimensions (WxHxD) (in.)
7.72 x 12.27 x 16.38 |
Dimensions (WxHxD) (mm.)
196 x 337 x 416 |
Weight (lbs.)
62.17 |
Weight (kg.)
28.2 |
SHIPPING DIMENSIONS
Dimensions (WxHxD) (in.)
11.61 x 18.03 x 20.43 |
Dimensions (WxHxD) (mm.)
295 x 458 x 519 |
Weight (lbs.)
67.02 |
Weight (kg.)
30.4 |
ENVIRONMENTAL
Operating Temperature (°F)
32 ~ 104 |
Operating Temperature (°C)
0 ~ 40 |
Operating Relative Humidity (Non-condensing) (%)
20 ~ 90 |
Operating Elevation (feet/meters)
0-5,000 feet (0-1,500 meters) |
Storage Temperature (°F)
-4 ~ 122 |
Storage Temperature (°C)
-20 ~ 50 |
Storage Relative Humidity (Non-condensing) (%)
10 ~ 90 |
Storage Elevation (feet/meters)
0-5,000 feet (0-1,500 meters) |
Online Thermal Dissipation (BTU/hr)
1126 |
Audible Noise at 1.5M from Surface of Unit (dBA)
45 |
CERTIFICATIONS
Certifications
CE , RCM |
RoHS
Yes |
WARRANTY
Product Warranty Period (Year)2
Battery Warranty Period (Year)2